5266 Transformer Tester

5266 Transformer Tester

1000.00 - 3000.00 INR/Unit

Product Details:

  • Application For Industrial Use
  • Material Aluminum
  • Color White
  • Voltage 110 Volt (v)
  • Product Type Transformer Test System
  • Click to View more
X

5266 Transformer Tester Price And Quantity

  • 1000.00 - 3000.00 INR/Unit
  • 1 Unit

5266 Transformer Tester Product Specifications

  • For Industrial Use
  • Transformer Test System
  • 110 Volt (v)
  • White
  • Aluminum

5266 Transformer Tester Trade Information

  • 1000 Unit Per Month
  • 3 - 4 Week
  • All India

Product Description

Model 5266 Transformer Tester have trail frequency between 20Hz~200kHz and 48 test points. By employing newly patent design, this model is capable to cater to the requirements for multi-pin system transmission transformer under the exact volume trend. To avert the attachment interference from impacting firm values in the course of testing. The software has a function of elevated frequency function, which enables the readings from attachment are nearly identical as measured estimates that enhances the credibility of the tester. This is the optimum selection for availing transform testers as they find their usability in transformers of power ans network transmission and others.

Technical Specifications

Measurement Data


Frequency

20Hz-500KHz

Turn Ratio Frequency

50Hz ~ 200kHz(10Vac Max.)

Measurement Parameters

Inductance (L)Impedance (Z)Capacitance (C)Resistance (R)Conductance (G)Susceptance (B)Admittance (Y)Alternating Current Resistance (ACR)Quality Factor (Q)Phase angle(Ø)Direct Current Resistance (DCR)Leakage InductanceTurn RatioBalanceShort Circuit

Basic Accuracy

±0.1%(AC parameter : 1KHz)

Output Impedance

100Ω

Frequency trimming resolution

5digits

Frequency output accuracy

±0.01%

Point of Test

20 Points

ESR

Series/Parallel

Mathematical Mode

Absolute/Percentage

Calibration

Open Circuit/ Short Circuit


Power Supply

Voltage98Vac~132Vac or 195Vac~264Vac/47Hz~63Hz

Frequency 48Hz ~ 62Hz

Display

800*4807" TFT LCD

Interface

RS-232, LAN, Handler, USB Host

Flash Memory

128 sets

Operation

AutoManualRemote Trigger

Environment

Temperature : 10 ~ 40 Humidity : 20% ~ 90%

Dimension (W*H*D)

344x145x343 mm



Parameters Measurement Ranges


Parameter

Range

Basic Accuracy
(AC parameter : 1KHz)

speed

L, LK

0.1nH ~ 9999.99H

0.1%

25ms

C

0.00001pF ~ 999.99mF

0.1%

25ms

Q,D

0.00001 ~ 99999

0.0005

25ms

Z,X,R

0.00001Ω ~ 99.9999MΩ

0.1%

25ms

Y

0.01nS ~ 99.9999S

0.1%

25ms

θ

-180°~ +180°

0.03°

25ms

DCR

0.1mΩ ~ 99.999 MΩ

0.1%

25ms

Turn

0.1 ~ 99999.9 turns

0.5%

50ms

Pin-Short

12 pairs, between pin to pin

--

15ms